RoVal Manufacturing Corp

Problem Solvers

Blotchy Areas:

CAUSES

Moisture in the surface, when the sealer is applied, can result in a blotchy looking floor, especially when using penetrating type sealers.  Given enough time, the floor will clear on its own, due to the breathability of penetrating impregnators. 

Uneven application of coating type sealers may also result in a blotchy look.  The floor will look like it has "highs and lows" or glossy and enhanced color in some areas and no gloss, no color enhancement in other areas.   This will usually happen on the second application of solvent based coatings, when applied to highly porous surfaces, and is the result of irregular absorption of the sealer.  This will usually dry uniform, without blotches, after several coats.

REMEDIES & PREVENTION

Always allow adequate time for the floor to completely dry before applying any type of sealer.  Become familiar with the unique characteristics of the sealer that you are using.  Always do test areas before approving and always apply sealer exactly like the label instructs.

 

Phone:  813.988.4910
Fax:  813.988-4840

 

Back to Problem Solvers

 


 